Determination of 6 Hazard Elements in Spatholobi Caulis by ICP-MS and Its Limit Assessment
-
Graphical Abstract
-
Abstract
OBJECTIVE To develop a method for the determination of 6 hazard elements such as Cr, Cu, As, Cd, Hg and Pb in Spatholobi Caulis. METHODS After the microwave digestion and then 6 hazard elements were determined by ICP-MS at the same time. Based on this, the limit of Cr, Cu, As, Cd, Hg and Pb were assessed with WHO standards. RESULTS The determination results of 6 hazard elements all have a good linear relationship, r≥0.9998. The limit of detection was range from 0.0016~0.0227ng/mL, the average recovery was 70.05%~117.98%, and RSD were 1.30%~3.69%. Determination results of samples of 6 hazard elements less than the maximum limit value(0.8000, 140.0, 0.8571, 0.4000, 0.2286, 1.429mg/kg). CONCLUSION The method is simple, accurate and high sensitive, can be used for the quality control and limit assessment of Spatholobi Caulis.
-
-